fix required flags

This commit is contained in:
Pieter Hollander 2025-01-04 21:43:55 +01:00
parent ad5dfd3e6d
commit d95ef0100f
Signed by: pieter
SSH key fingerprint: SHA256:HbX+9cBXsop9SuvL+mELd29sK+7DehFfdVweFVDtMSg

View file

@ -34,11 +34,11 @@ Leave the other settings as-is. Save the configuration, go to the "Info" tab and
With the database initialised, we can now setup OpenDTU Logger. Add the [add-on repository](https://git.hollander.online/energy/home-assistant-addons) using the [instructions](https://git.hollander.online/energy/home-assistant-addons) provided. Then, click "Install" to install this add-on. Go to "Configuration" and set the following variables:
- `db`
- `db` **(required)**
- If you're using Expaso's TimescaleDB add-on as described above, the `db` setting will **not** require any changes.
- `opendtu_address` **(required)**
- In the `opendtu_address` field, enter the *IP address* or *hostname* of your OpenDTU. E.g.: `192.168.1.5` or `opendtu.local`.
- `opendtu_auth` *(optional)* / **(required)**
- `opendtu_auth` (*optional* / **required**)
- If your OpenDTU is password-protected, setting the following variables is required.
- `opendtu_auth`: If applicable, enable this setting.
- `opendtu_username`: `admin`
@ -50,7 +50,7 @@ With the database initialised, we can now setup OpenDTU Logger. Add the [add-on
- If you are living in a different location, you can find the timezone identifier of your location using [this list](https://en.wikipedia.org/wiki/List_of_tz_database_time_zones#List).
- `timescaledb` *(optional)*
- If you don't want to use TimescaleDB, disable `timescaledb`.
- `log_level`
- `log_level` **(required)**
- By default, `log_level` is set to `INFO`, which is recommended for most users.
- Other valid options are `DEBUG`, `INFO`, `WARN` and `ERROR`.