No description
Find a file
Pieter Hollander 19aca3e910
All checks were successful
Build Docker image / build (push) Successful in 1m12s
Build Golang packages / release (push) Has been skipped
Fix tables. Better text structure.
2024-03-20 01:12:00 +01:00
.gitea/workflows Add CI for binary releases. 2024-02-22 11:42:04 +01:00
.gitignore Add ignore. 2024-02-17 16:52:59 +01:00
chatgpt prompt.md First commit. 2023-12-05 17:37:50 +01:00
compose.timescaledb.yml typo. 2024-02-20 18:05:01 +01:00
compose.yml Make using TimescaleDB optional. 2024-02-20 18:04:30 +01:00
Dockerfile Fix rename omission. 2023-12-05 17:45:12 +01:00
example.env Make using TimescaleDB optional. 2024-02-20 18:04:30 +01:00
go.mod Downgrade go due to docker build support. 2024-02-22 12:25:59 +01:00
go.sum First commit. 2023-12-05 17:37:50 +01:00
main.go Update doc. Fix TimescaleDB integration. 2024-03-20 00:42:34 +01:00
README.md Fix tables. Better text structure. 2024-03-20 01:12:00 +01:00

P1 logger

P1 logger is a tool designed to store meter data conforming to the ESMR or DSMR (European / Dutch Smart Meter Requirements) standard as efficiently as possible in a PostgreSQL database.

Data storage architecture

To store the data as efficiently as possible, a few design choices had to be made.

All metrics are stored as INT and not NUMERIC or FLOAT to optimise their storage size.

Dt1, Dt2, Rt1, Rt2, G, F and Fl are cumulative meter readings. Therefore, they function as counters that can only go up. By making them pointers to int, they can be set to 'nil' when the reading has not changed. This way, they are logged as NULL in the database when no change has happened, saving storage capacity. As an added benefit, this also make data retrieval, visualisation and analysis more light-weight.

Gas consumption is updated once per minute. Not saving intermittent values theoretically saves 4 bytes per value. An average month has 43,829.0639 minutes. 4*43,829.0639 = 175,316.26 bytes = 0.18 MB

In practice, storage will be even lower when gas is not being consumed continuously, as a new metric won't be available for every minute.

When Tariff 1 is active, Tariff 2 isn't. When energy is being imported, it is not being returned.

Therefore, only updating their values on-change should save at least 75% storage capacity requirements An average month has 2,629,743.83 seconds.

This saves at least: 2,629,743.83 seconds * 4 bytes = 10,518,975.32 bytes = 10,518.98 kB = 10.52 MB This applies both to Dt1 and Dt2 as well as Rt1 and Rt2, only one is recorded at a time. 10.52 * 3 = 31.56 MB.

In addition, many meters only update these metrics once every 10 seconds, meaning even more storage capacity is saved: 10.52 / 10 * 9 = 9,468 MB.

For D1-3 and R1-3, either Dx or Rx will be active. Therefore, their storage requirements can be sliced in half, saving 3 * 10.52 = 42.08 MB. This is different for D and R, as these contain the sum of each phase and are reported simultaneously. Not saving failures when there is no change, will save around 10.52MB per month per metric, so an additional 21.04MB.

Theoretical storage requirements for a DSMR5 meter with metrics emitted every second

Column Column size (bytes) Per month (MB) X Total (MB)
Timestamp 8 bytes 21.04
Dt1, Dt2, Rt1, Rt2 4 bytes 1.05
D, R 4 bytes 10.52
R 4 bytes 10.52
F 4 bytes 0.00
Fl 4 bytes 0.00
G 4 bytes 0.18
V1-3, C1-3 4 bytes 10.52 6 63.12
D1-3, R1-3 4 bytes 10.52 3 31.56
Total 137.99

Theoretical storage requirements without optimisations:

Column Column size (bytes) Per month (MB) X Total (MB)
Timestamps 8 bytes 21.04
Values 4 bytes 10.52 21 220.92
Total 241.96

Conclusion

At the expense of having to create more complicated queries for analysis and visualisation, the optimisations save at least 103.97 MB or 1-137.99/241.96 = 43% in uncompressed storage space per month.

Columns

Data is stored in a table containing the following columns

  • timestamp
  • delivered_tariff1, delivered_tariff2, returned_tariff1, returned_tariff2
  • delivery_all
  • returning_all
  • failures
  • long_failures
  • gas
  • voltage_l1, voltage_l2, voltage_l3
  • current_l1, current_l2, current_l3
  • delivery_l1, delivery_l2, delivery_l3
  • returning_l1, returning_l2, returning_l3

Input: P1 reader

P1 Logger relies on a JSON input provided by a P1 reader.

The reader should send its data to an MQTT broker in the following JSON structure

References