No description
Find a file
Pieter Hollander 1ca6e2085c
Some checks failed
Build Golang packages / release (push) Waiting to run
Build Docker image / build (push) Has been cancelled
Improve README.md
2024-06-15 20:56:56 +02:00
.gitea/workflows Add CI for binary releases. 2024-02-22 11:42:04 +01:00
screenshots Improve README, add screenshot. 2024-06-15 15:06:32 +02:00
.gitignore Add ignore. 2024-02-17 16:52:59 +01:00
compose.timescaledb.yml typo. 2024-02-20 18:05:01 +01:00
compose.yml Make using TimescaleDB optional. 2024-02-20 18:04:30 +01:00
Dockerfile Fix rename omission. 2023-12-05 17:45:12 +01:00
example.env Make using TimescaleDB optional. 2024-02-20 18:04:30 +01:00
go.mod Downgrade go due to docker build support. 2024-02-22 12:25:59 +01:00
go.sum First commit. 2023-12-05 17:37:50 +01:00
LICENSE.md Add LICENSE.md 2024-06-15 14:58:08 +02:00
main.go Update doc. Fix TimescaleDB integration. 2024-03-20 00:42:34 +01:00
README.md Improve README.md 2024-06-15 20:56:56 +02:00

P1 logger

P1 logger is a tool designed to store meter data conforming to the ESMR or DSMR (European / Dutch Smart Meter Requirements) standard as efficiently as possible in a PostgreSQL database. Optionally, TimescaleDB is supported.

P1 logs visualised in Grafana

Background: data storage architecture

P1 logger aims to store detailed meter data as efficiently as possible. Therefore, a few design choices were made.

All metrics are stored as INT and not NUMERIC or FLOAT to optimise their storage size.

Dt1, Dt2, Rt1, Rt2, G, F and Fl are cumulative meter readings. Therefore, they function as counters that can only go up. By making them pointers to int, they can be set to 'nil' whenever a reading has not changed. This way, they are logged as NULL in the database when no change has happened, saving storage capacity. As an added benefit, this makes data retrieval, visualisation and analysis more light-weight.

Typical P1 meters update gas consumption once per minute. Not saving intermittent values theoretically saves 4 bytes per value. An average month has 43,829.0639 minutes. 4*43,829.0639 = 175,316.26 bytes = 0.18 MB

In practice, storage will be even lower, as gas is usually not consumed continuously. Therefore, a new metric won't be available for every minute.

When Tariff 1 is active, Tariff 2 isn't. When energy is being imported, it is not being returned. Therefore, only updating their values on-change should save at least 75% storage capacity requirements An average month has 2,629,743.83 seconds.

This saves at least: 2,629,743.83 seconds * 4 bytes = 10,518,975.32 bytes = 10,518.98 kB = 10.52 MB This applies both to Dt1 and Dt2 as well as Rt1 and Rt2, only one is recorded at a time. 10.52 * 3 = 31.56 MB.

In addition, many meters only update these metrics once every 10 seconds, meaning even more storage capacity is saved: 10.52 / 10 * 9 = 9,468 MB.

For D1-3 and R1-3, either Dx or Rx will be active. Therefore, their storage requirements can be sliced in half, saving 3 * 10.52 = 42.08 MB. This is different for D and R, as these contain the sum of each phase and are reported simultaneously. Not saving failures when there is no change, will save around 10.52MB per month per metric, so an additional 21.04MB.

Theoretical storage requirements for a DSMR5 meter with metrics emitted every second

Column Column size (bytes) Per month (MB) X Total (MB)
Timestamp 8 bytes 21.04
Dt1, Dt2, Rt1, Rt2 4 bytes 1.05
D, R 4 bytes 10.52
R 4 bytes 10.52
F 4 bytes 0.00
Fl 4 bytes 0.00
G 4 bytes 0.18
V1-3, C1-3 4 bytes 10.52 6 63.12
D1-3, R1-3 4 bytes 10.52 3 31.56
Total 137.99

Theoretical storage requirements without optimisations

Column Column size (bytes) Per month (MB) X Total (MB)
Timestamps 8 bytes 21.04
Values 4 bytes 10.52 21 220.92
Total 241.96

Real-world experiences

At the expense of having to create more complicated queries for analysis and visualisation, the optimisations save at least 103.97 MB or 1-137.99/241.96 = 43% in uncompressed storage space per month. In practice, the storage requirements are lower than those mentioned in the aforementioned theoretical calculations. Over 8 months, I collected a database of 1.04GB of metrics. Using ZSTD with the default level 3, the database can be compressed to just 12.77% of this.

zstd p1_backup.sql         
p1_backup.sql        : 12.77%   (  1.04 GiB =>    136 MiB, p1_backup.sql.zst)  

It is therefore recommended to use filesystems supporting compression, such as BTRFS. The P1 logger operating on a btrfs filesystem with compression enabled at default levels, can store the aforementioned 1.04GB of metrics in just 136MB of physical disk space. With the highest ZSTD compression level, 19, the 1.04GB database is stored in just 8.14% of its original size.

zstd -19 p1_backup.sql
p1_backup.sql        :  8.14%   (  1.04 GiB =>   86.6 MiB, p1_backup.sql.zst)

Storage requirements conclusion

Theoretically, but based on real-world data, a full year of P1 metrics logged by this program can be stored in in around 233MB of physical disk space.

Columns

Data is stored in a table containing the following columns

  • timestamp
  • delivered_tariff1, delivered_tariff2, returned_tariff1, returned_tariff2
  • delivery_all
  • returning_all
  • failures
  • long_failures
  • gas
  • voltage_l1, voltage_l2, voltage_l3
  • current_l1, current_l2, current_l3
  • delivery_l1, delivery_l2, delivery_l3
  • returning_l1, returning_l2, returning_l3

Input: P1 reader

P1 Logger relies on a JSON input provided by a P1 reader.

The reader should send its data to an MQTT broker in the following JSON structure

TODO

This is currently achieved using an ESP32 with ESPhome. Configuration files will be added soon.